Sinclair SMF-C09AI Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Climatiseurs à système divisé Sinclair SMF-C09AI. Sinclair SMF-C09AI User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 27
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS
Technical service manual
R410A Cassette Inverter multi Series
Indoor Models
SMF-C09AI
SMF-C12AI
SMF-C18AI
Outdoor Models
SMF-4E27AI
Vue de la page 0
1 2 3 4 5 6 ... 26 27

Résumé du contenu

Page 1 - Technical service manual

1 MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual R410A Cassette Inverter multi Series Indoor Models SMF-C09

Page 2

104.Indoor unit combination: Caution on combination The one-drive-four outdoor unit SMF-4E27AI nominal cooling capacity is 8kw(under condition of am

Page 3 - 1. Features:

11 5. Capacity table SMF-4E27AI (7k+7k+7k+7k) COOLING OUTDOOR TEMPERATURE DRY Indoor Conditions 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC Total c

Page 4 - 2.Specification

126. WIRING DIAGRAM Indoor unit:

Page 5

13Outdoor unit (SMF-4E27AI)

Page 6

147. Electric control functions: 7.1 Protection 1. 3 minutes delay at restart for compressor. 2. Temperature protection of compressor top, compres

Page 7 - Electronic control

157.2.2 Dehumidifying mode 1.The indoor fan is fixed in low speed 2. Low room temperature protection: When room temperature decreases to below 10℃,

Page 8

16If one of following conditions is satisfied, end the defrost and turn into heating mode: a. The defrost time has reached to 10 minutes. b. When th

Page 9 - 3.Outline and dimension

171. The maximum length of timer is 24 hours and the minimum resolving power is 15 minutes. 2. Timer on: first turn off the A/C, the A/C will be au

Page 10 - 4.Indoor unit combination:

187.9 Outdoor unit LED display function: 1. When stand-by it display number of indoor unit online; 2. When operation it display frequency of outdoor

Page 11 - SMF-4E27AI (7k+7k+7k+7k)

192. Fan state: Display Corresponding mode 0 Off 1 Low fan 2 High fan 3. Opening degree of EXV: Opening degree equals the display data times 8

Page 12 - Indoor unit:

2 CONTENTS 1. Features 2. Specification 3. Outline and dimension 4. Indoor unit combination 5. Capacity table 6. Wiring diagram 7. Electronic cont

Page 14 - 7.2 Operating mode

2112 Pipe Temperature Sensor Ass'y 1 50118121032 2244050004 13 Evaporator Ass'y 1 50118121011 2154209004 14 Fixing clamp, eva

Page 16 - 7.3 Mode conflict

2311 Drain Pump Holder 1 50112111010 2124200409 12 Pipe Temperature Sensor Ass'y 1 50118121032 2244050004 13 Evaporator Ass'y

Page 18 - 7.10 Check function:

2515 Deseparating board, left 1 50112111012 2124200404 16 Inlet pipe, eva 1 50118121009 2164209006 17 Outlet pipe, eva 1 50118121002 216

Page 19 - 7.12 Oil return function

26SMF-4E27AI 1 Clamp for front net 8 2113511801 2 Propeller fan 1 2114550002 3 Holder for fan motor 1 2123549027 4 fan motor 1 22400417

Page 20

2712 electrical box assembly 1 2335739000 13 Rear net 1 2114820000 14 Condenser Ass'y 1 2154709047 15 Handle 2 2114540003 16 D hig

Page 21 - 2110011001

3 1. Features: 1) Fashion design, quality life; 2) Low operation noise; 3) High efficiency screw fan; 4) Equal, fast, wide-angle cooling, more comfo

Page 22

42.Specification indoor unit Model SMF-C09AI SMF-C12AI SMF-C18AI Power supply Ph-V-Hz 1Ph,220-240V~,50Hz

Page 23

5Net/Gross weight(body) Kg 21/28 21/28 28/36 Dimension (W*H*D) mm 650x30x650 650x30x650 650x30x650 Packing (W*H*D) mm 715x115x715 715x11

Page 24

6OUTDOOR UNIT: Outdoor Model SMF4E27AI Indoor unit combination single double Treble Quadplex Power supply Ph-V-Hz 1Ph,220-240V~,50Hz Cooling

Page 25

7Input W 169(HIGH) Capacitor uF 5uF/500VAC Speed r/min 900(HIGH) a.Number of rows 2 b.Tube pitch(a)x row pitch(b) mm 25.4×22 c.Fin spac

Page 26 - SMF-4E27AI

8Qty’per 20’ /40’ /40'HQ set Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27°CDB, 19°CWB; Ou

Page 27

9 3.Outline and dimension Indoor unit(7k/9k/12k/18k): 580(Body)67600(Ceiling hole)650(Panel)401(Hook-location)611(Hook-location)580(Body)422 28.5600

Commentaires sur ces manuels

Pas de commentaire